HIGH-THROUGHPUT
PURIFICATION SYSTEMS: THOMSON INSTRUMENT COMPANY
Thomson
Instrument Company has available
its SINGLE StEP
Flash Chromatography Column (patented) product line of pre-packed
columns (EM Silica, Standard Silica, C-18, and Amine) for sample
flash column chromatography purification of samples ranging from
50 mg to 17 grams.
The SINGLE
StEP™ Columns have many advantages besides being the “Original Screw-Top”.
SINGLE StEP™ Columns are easily wet & dry loaded. The SINGLE
StEP™ screw-top design allows the loading of hard to push-on oily
substances, and other powder options.
The SINGLE
StEP™ columns
allow for loading samples dry (dry loading) or in solution (liquid
loading) directly on the columns. Frits can be used to compac loaded
samples when dry loading.

SINGLE
StEP™ Columns from 4g-90g.
|

SINGLE
StEP™ Columns from 100g-300g.
|
These
columns cover the following sample purification ranges:
- SINGLE StEP
4g: 50mg-200mg of sample (solvent flow: 6mL/min-20mL/min).
- SINGLE StEP
12g: 300mg-600mg of sample (solvent flow: 6mL/min-20mL/min).
- SINGLE StEP
25g: 700mg-1.4g of sample (solvent flow: 15mL/min-35mL/min).
- SINGLE StEP
40g: 1.5g-2.5g of sample (solvent flow: 15mL/min-40mL/min).
- SINGLE StEP
80g: 2.6g-4.1g of sample (solvent flow: 17mL/min-50mL/min).
- SINGLE StEP
90g: 4.2g-5.6g of sample (solvent flow: 17mL/min-50mL/min).
- SINGLE StEP
110g: 5.8g-6.5g of sample (solvent flow: 24mL/min-50mL/min).
- SINGLE StEP
160g: 7.2g-8.4g of sample (solvent flow: 28mL/min-50mL/min).
- SINGLE StEP
240g: 11.5g-13.8g of sample(solvent flow: 50mL/min-85mL/min).
- SINGLE StEP
300g: 14.4g-17.0g of sample (solvent flow: 50mL/min-85mL/min).
The
SINGLE
StEP columns
are closed with screw-down caps which come with standard luer fittings
making the columns compatible with a variety of purification systems
such as Thomson's SINGLE StEP™ Pump, Biotage® and ISCO®
systems.

SINGLE
StEP™ 4g-90g columns
with SINGLE StEP™ pump
|

SINGLE
StEP™ 4g-90g columns
with Biotage's® system
|

SINGLE
StEP™ 4g-90g columns
with ISCO's® system
|

SINGLE
StEP™ 100-300g columns
with SINGLE StEP™ pump
|

SINGLE
StEP™ 100-300g columns
with Biotage's® system
|

SINGLE
StEP™ 100-300g columns
with ISCO's® system
|
Thomson
offers its SINGLE
StEP™ pump, a robust, modular liquid pump that is compatible with
halogenated and non-halogenated solvents. This pump is light weight
and has a 4" x 5" small footprint making it easy to transport
and place on workbenches and hoods. The SINGLE StEP™ Pump can also
work with fraction collectors.

SINGLE
StEP™ Pump
|

SINGLE
StEP™ Pump with fraction collector
|
The SINGLE
StEP™ Pump is availabe in 3 models: 1mL-100mL for 50 mg-15 gram
scale, 20mL-400mL for 5 gram-50 gram scale, and
44mL-1Liter/minute for 10 gram-100 gram scale.
The
efficiency of the StEP
columns
is shown below:
|
|

Before
TLC
|

After
TLC
|

For
more information on Thomson's SINGLE
StEP columns
and SINGLE
StEP pumps
click
here.
Thomson
Instrument Company is not affiliated with Biotage A.B.® , E.M.
Sciences®, or Isco/Teledyne Inc.®
SP-1™,
SP-4™ , and Horizons are Trademarks of Biotage A.B.® ; E.Merck®
is registered to EMD Chemicals, Inc.
The
SINGLE StEP